20 Amp 15m 4 Pin, 3 (Three) Phase 415V Light Industrial Ext Lead.
11770 Views
- Brand: EEC Technical Services
- MPN: EEC 4004_15
- 4 Available
-
$227.00
- Ex Tax: $206.36
Available Options
Shipping Estimate
20 Amp Australian 3 (Three) Phase(415V)
Light Duty
Industrial Extension Lead
Cord Length: 15 m
Light Duty:
Light Duty:
The “Light Duty” extension lead is suitable for indoor and short-duration outdoor use.
The “light” extension lead has the shortest maximum length allowed from the
outlet to the appliance.
These light-duty extension leads are recommended for indoor use or outdoor
applications where the ambient temperature is below 40°C.
For extended use outdoors or in environments with high ambient temperatures, use the Heavy
extension leads.
(Intermittent use: Ambient temperature above 40°C below 45°C)
The maximum length for general use is 30m
The maximum length for use with any equipment that has a high starting current is 10m
Applications:
- Wet and oily environments
- Construction site leads
- Flexible connections to motors, generators, compressors, e.g.
- Drills & pumps
- Saws & log splitters
- Cranes & Hoists
- Handheld drills
- Grinders & welders
- Agricultural equipment
- Generators
- 3 phase Vacuums & floor grinders. etc
- Event and temporary cabling, e.g.
- fairgrounds
- sporting venues
- Stage & theatre power.
The extension lead is suitable for dry, damp and wet environments; areas of stress caused by vibration or impact are resistant to abrasion, exposure to radiated heat and chemical contamination. The black, flame-retardant sheath is suitable for areas subject to fire hazards and hazardous locations like engineering workshops. For applications where the lead is dragged behind a machine during normal operation, e.g., floor polishers, floor grinders, etc.
Maximum Ambient temperature: 40°C
Maximum Continuous Length: 30m
Maximum current at 40°C: 20A
Cable Specifications:
Cable CSA:2.5mm²
Max Voltage: 06/1kV
Insulation: Ethelyne-propylene rubber (EPR) R-EP-90 90 deg C Conductor
Sheath Colour: Black - UV, sunlight and weather resistant.
Cable Temperature Range: -25 degrees C to +90 degrees C (mobile) -40 degrees c to +90 degrees C (fixed)
Maximum permissible short circuit temperature: 250 deg C for 1 Sec
EEC is an online mail-order store; customer pickup is not available
The “Light Duty” extension lead is suitable for indoor use and short duration outdoor use.
The “light” extension lead has the shortest maximum length allowed from the
outlet to the appliance
These light duty extension leads are recommended for indoor use or for outdoor
applications where the ambient temperature is below 40°C.
For extended use outdoors or in environments with high ambient temperatures use the Heavy
extension leads.
(Intermittent use: Ambient temperature above 40°C below 45°C)
The maximum length for general use: 30m
The maximum length for use with any equipment that has a high starting current: 10m
Applications:
- Wet and oily environments
- Construction site leads
- Flexible connections to motors, generators, compressors e.g.
- Drills & pumps
- Saws & log splitters
- Cranes & Hoists
- Handheld drills
- Grinders & welders
- Agricultural equipment
- Generators
- 3 phase Vacuums & floor grinders. etc
- Event and temporary cabling e.g.
- fairgrounds
- sporting venues
- Stage & theatre power.
The extension lead is suitable for dry, damp and wet environments; areas of stress caused by vibration or impact they are resistant to abrasion, exposure to radiated heat and chemical contamination. Because of the black, flame retardant sheath, it is suitable for areas subject to fire hazard and hazardous locations like engineering workshops.
It is that recommended for applications where the lead is continually dragged behind a machine, e.g., floor polishers, floor grinders, etc.
Maximum Ambient temperature: 40°C
Maximum Continuous Length: 30m
Maximum current at 40°C: 20A
Cable Specifications:
Cable CSA:2.5mm²
Max Voltage: 06/1kV
Insulation: Ethelyne-propylene rubber (EPR) R-EP-90 90 deg C Conductor
Sheath Colour: Black - UV, sunlight and weather resistant.
Cable Temperature Range: -25 deg C to +90 deg C (mobile) -40 deg c to +90 Deg C (fixed)
Maximum permissible short circuit temperature: 250 deg C for 1 Sec
EEC is an online mail order store, customer pickup is not available
Related Products
Tags: 20 Amp 15m 4 Pin, 3 (Three) Phase 415V Light Industrial Ext Lead, 20 Amp 4 Pin Light Industrial Extension Lead